Semi-enclosed refrigeration compressor has these problems as long as this can be easily solved
Short skirt, air conditioning, ice cream seems to be our impression of summer, the most cool thing in summer is covered with a quilt blowing air conditioning playing mobile phone eating Popsicle bar, Popsicle production need to use semi-closed refrigeration compressor, can provide a low temperature environment for production and preservation. However, if the semi-closed refrigeration compressor appears these problems need to be dealt with in time.
1. Sudden power failure and shutdown
If there is a sudden power failure when the refrigeration compressor is running, the power switch should be cut off and the suction valve and exhaust valve of the compressor should be immediately closed. At the same time, the liquid supply valve should be closed to stop the liquid supply to the evaporator, so as to avoid the wet compression caused by too much liquid in the evaporator when the machine is started next time.
2. Sudden water shutdown and stop
If the cooling water is interrupted suddenly, the power supply should be cut off immediately and the operation of the refrigeration compressor should be stopped to avoid high pressure of the condenser. After the compressor is shut down, the suction and exhaust valves and the liquid supply valves of the compressor should be closed immediately. Start the compressor after the fault is eliminated and the water supply is restored.
3, refrigeration compressor failure stop
In operation, when a compressor component is damaged and in urgent need of shutdown, if time permits, it can be operated according to the normal shutdown. If the situation is urgent, it is necessary to cut off the motor power supply and close the suction, exhaust valve and liquid supply valve. If the refrigeration equipment runs ammonia or the refrigeration compressor breaks down, cut off the power supply in the workshop and wear anti-virus clothing and masks for urgent repair. At this time, all exhaust fans should be opened, and if necessary, the ammonia leakage can be poured with water to facilitate emergency repair.
4. Stop in case of fire
If a fire occurs in an adjacent building and endangers the safety of the refrigeration system, the power supply should be cut off, and the exhaust valves of the liquid reservoir, condenser, ammonia oil separator and evaporator should be opened quickly, and the emergency ammonia discharger and its water valve should be opened quickly, so that the ammonia liquid of the system can be concentrated and discharged at the emergency ammonia discharger and diluted by a large amount of water to prevent the fire from spreading and causing an explosion.
5, wet stroke stop
In operation, if the wet stroke of the refrigeration compressor occurs, it should be treated according to its severity. For slight wet stroke, the suction valve or expansion valve should be turned down or closed. For more serious wet stroke, the suction valve and expansion valve should be shut down immediately. After serious wet travel, the refrigerant in the crankcase should be discharged, or other refrigeration compressor should be used to extract the refrigerant in the crankcase and the cylinder, and the lubricating oil should be replaced at the same time. After vacuuming, pressure test and leakage detection, the test machine can be started.
The quality of semi-closed refrigeration compressor will determine the refrigeration capacity and refrigeration cost, so consumers must see clearly at the time of purchase, do not choose the quality of the semi-closed refrigeration compressor, or increase the cost is small, failure affects the whole production is a big trouble.